Skip to main content
  • Research article
  • Open access
  • Published:

Computed tomography measurement of glenoid vault version as an alternative measuring method for glenoid version

Abstract

Background

The conventional measuring method for glenoid version is greatly influenced by the scapular body shape that varies widely between patients. We postulated that the glenoid vault version could be more useful than the conventional glenoid version in clinical cases.

Objectives

The purposes of this study were to compare the values of glenoid version measured with the conventional method to those with the vault method and to investigate the feasibility of the glenoid vault version.

Methods

Computed tomography scans of 150 normal shoulders and 150 arthritic shoulders were analyzed. Three-dimensionally corrected slices were reconstructed from the Digital Imaging and Communications in Medicine (DICOM) data, and glenoid version was measured with both the conventional and vault methods. After determining intra- and interrater reliabilities, differences in glenoid version values between the conventional and vault methods were assessed. In the normal shoulder group, side-to-side differences of glenoid version values were also evaluated in both methods.

Results

Both measuring methods demonstrated high intra- and interrater reliabilities. The normal glenoid had 1.1° ± 3.2° retroversion with the conventional method and 8.9° ± 2.7° retroversion with the vault method. The average glenoid retroversion of arthritic shoulders was 10.8° ± 9.3° measured with the conventional method and 18.2° ± 9.1° with the vault method. The vault method showed significantly larger glenoid retroversion than the conventional method in both normal and arthritic shoulder groups. Both conventional glenoid retroversion and glenoid vault retroversion were significantly larger on dominant sides than on nondominant sides in the normal shoulders.

Conclusions

The glenoid vault version could be used as an alternative measuring method for glenoid version with high reliability. In clinical use, the glenoid vault version appears to be more useful than the conventional glenoid version to assess the severity of arthritis and difficulty of glenoid replacement. The glenoid vault is not symmetric, but usually retroverted in both normal and arthritic shoulders.

Introduction

Proper recognition of the individual glenoid version is important for anatomical reconstruction in shoulder arthroplasty[13]. Computed tomography (CT) evaluation is the most popular method for the measurement of glenoid version in clinical cases[48]. The conventional measuring method for glenoid version described by Friedman et al. has been widely utilized[4], and normal shoulders are expected to have neutral version in accordance with a small number of past studies[4, 5, 9]. However, the conventional method is sensitive to the scapular body shape that varies widely between patients. The conventional glenoid version should be considered as a ‘scapular version’ rather than a ‘glenoid version,’ and we propose to use the glenoid vault method as an alternative measuring method for glenoid version in order to exclude the influence of the scapular body shape and to attain more accurate values.

We hypothesized that the conventional measuring method and the glenoid vault method would give different values of glenoid version and that the glenoid vault would have larger retroversion than had previously been thought. The purposes of this study were to compare the values of glenoid version measured with the two methods and to assess the feasibility of the glenoid vault version.

This study was approved by the Institutional Review Board of Centre Orthopédique Santy et Hôspital Privé Jean Mermoz (reference study number 45).

Patients and methods

Both normal and pathological shoulders were examined in this study. The normal shoulder group prospectively included axial CT scans of 150 shoulders from 75 healthy volunteers ranging from 20 to 30 years of age (mean age, 26.5 ± 2.6 years; 38 males and 37 females). All volunteers gave informed consent to participate in this study, and candidates with any past illnesses or injuries in the shoulder girdles were excluded. All of them were engaged in light work, and no one performed heavy labor or competitive sports activity at the time of investigation. The dominant shoulders were right in 69 and left in 6. Bilateral CT scans with 3-mm-thick contiguous glenoid slices were taken with the elbow extended, the forearm supinated, and the palm fixed under the buttock to prevent arm motion (GE Healthcare HiSpeed NX/i Pro, Amersham, England, or Toshiba AquilionTM TSX-101A, Tokyo, Japan). The pathological shoulder group consisted of a retrospective review of 150 shoulders from 150 consecutive patients with primary glenohumeral arthritis (mean age, 68.4 ± 9.0 years; range, 41–89 years; 55 males and 95 females) who had unilateral CT arthrograms (Philips MX 8000, IDT 16, Amsterdam, Netherlands). The shoulders with previous surgeries involving the scapular region were excluded. The right shoulder was involved in 85 patients, and the left was involved in 65 patients. Thirty-four shoulders were classified using the Walch classification scheme[10] as type A1, 30 as type A2, 41 as type B1, 39 as type B2, and 6 as type C. All of the shoulders were positioned with neutral shoulder position during the examination. CT scans were taken with 0.4-mm-thick contiguous slices of the glenoid.

The obtained Digital Imaging and Communication in Medicine (DICOM) data were analyzed using the Osirix MD 1.4.1 software (Pixmeo, Geneva, Switzerland). In order to exclude the effect of scapular inclination, three-dimensionally corrected slices were reconstructed on the software[1, 11]. We determined the scapular plane as the plane including the inferior tip of the scapular body, the center of the glenoid surface, and the medial pole of the scapula[12]. The three-dimensionally corrected slice was reconstructed as the plane including the center of the glenoid surface and the medial pole of the scapula, and perpendicular to the scapular plane[13] (Figure 1). We examined glenoid version with the conventional measuring method described by Friedman et al.[4] (conventional method) and the glenoid vault method (vault method). Both methods defined the glenoid line as the line connecting the anterior rim with the posterior rim of the glenoid. The intermediate line was selected as the glenoid line[8] in the Walch classification[10] type B2 glenoid of the arthritic shoulders. The scapular axis was defined as the line connecting the tip of the medial border of the scapula and the center of the glenoid line in the conventional method. Glenoid version measured with the conventional method was calculated as the angle between the glenoid line and the line perpendicular to the scapular axis (Figure 2A,B,C). In the vault method, we defined the glenoid vault axis as the line connecting the tip of the scapular vault and the center of the glenoid line. Glenoid version with the vault method was calculated as the angle between the glenoid line and the line perpendicular to the glenoid vault axis (Figure 3A,B,C). Three evaluators independently reviewed all measurements twice with a minimum of a 1-month interval between measurements. Each measurement started from slice reconstruction.

Figure 1
figure 1

Reconstruction of three-dimensionally corrected slice. The inferior tip of the scapular body, the center of the glenoid surface, and the root of the scapular spine (the triangle made by the black dotted lines) are selected to determine the scapular plane (the plane surrounded by red lines). The plane including the scapular axis, which is defined as the line connecting the root of the scapular spine and the center of the glenoid surface (the black solid lines), and perpendicular to the scapular plane is reconstructed as the three-dimensionally corrected slice (the plane surrounded by blue lines).

Figure 2
figure 2

The conventional method for glenoid version measurement. The figures describe the conventional measuring method for glenoid version described by Friedman et al. The glenoid line is defined as the line connecting the anterior and the posterior rim of the glenoid (blue line). The scapular axis is defined as the line connecting the root of the scapular spine and the center of the glenoid line (red solid line). Glenoid version (α) is calculated as the angle between the glenoid line and the line perpendicular to the scapular axis (red dashed line). (A) The conventional method for measuring a normal shoulder. The scapular body shape appears flat. The glenoid shows 6.2° retroversion. (B) The conventional method for another normal shoulder. The scapular body shape is round. The glenoid shows 8.9° anteversion. The conventional method is sensitive to the scapular body shape that varies widely between patients. (C) The conventional method for measuring an arthritic shoulder. The scapular body is waving. CT arthrograms are used to measure glenoid version, and the glenoid has 28.3° retroversion. The intermediate line is selected as the glenoid line in the Walch classification B2 glenoid.

Figure 3
figure 3

The vault method as an alternative glenoid version measurement. The same cases as Figure 2 are measured with the vault method. The glenoid line is the same as that of the conventional method (blue line). The glenoid vault axis is defined as the line connecting the tip of the scapular vault and the center of the glenoid line (red solid line). Glenoid version measured with the vault method (β) is calculated as the angle between the glenoid line and the line perpendicular to the glenoid vault axis (red dashed line). (A) The vault method for measuring a normal shoulder. Glenoid vault retroversion is 9.7°. The difference between conventional glenoid version and glenoid vault version is only 3.5°. (B) The glenoid has 5.0° retroversion when measured with the vault method. The difference between conventional glenoid version and glenoid vault version amounts to 13.9°. (C) The vault method for measuring an arthritic shoulder. The glenoid vault has 34.8° retroversion. The difference between conventional glenoid version and glenoid vault version is 6.5°.

Statistical analyses were performed using IBM SPSS Statistics 20.0.0 software (IBM, Armonk, NY, USA). Intra- and interrater reliabilities were evaluated with intraclass correlation coefficients (ICCs) first. Glenoid version measurement reliability was examined in the normal and arthritic shoulder groups for both the conventional and vault methods. Intrarater reliability for each of three observers was calculated by repeated measurements with a 1-month interval (ICC model 1.1). Interrater reliability was calculated by blinded measurements of three observers (ICC model 2.1). After reliability was assessed, the glenoid version values were averaged across the three observers and their two measurements. The glenoid version values measured with the two methods were compared with the Wilcoxon signed-rank tests, and their distributions were compared using F-tests in both normal and arthritic shoulders. In the normal shoulders, differences of glenoid version values between the dominant and nondominant shoulders were compared using Wilcoxon signed-rank tests in both the conventional method and the vault method. The significance level was set at 0.05 for all analyses.

Results

Intrarater reliability of the three observers in conventional glenoid version measurement was 0.934 (95% confidence interval (CI), 0.910–0.952), 0.922 (95% CI, 0.894–0.943), and 0.904 (95% CI, 0.881–0.923) for normal shoulders and 0.976 (95% CI, 0.958–0.986), 0.959 (95% CI, 0.929–0.976), and 0.919 (95% CI, 0.861–0.953) for arthritic shoulders, respectively. Intrarater reliability of glenoid vault version was 0.901 (95% CI, 0.866–0.927), 0.914 (95% CI, 0.854–0.950), and 0.895 (95% CI, 0.859–0.923) for normal shoulders and 0.903 (95% CI, 0.835–0.944), 0.923 (95% CI, 0.869–0.956), and 0.930 (95% CI, 0.878–0.960) for arthritic shoulders, respectively. Interrater reliability of the conventional method was scored as 0.939 (95% CI, 0.920–0.954) for normal shoulder measurement and as 0.953 (95% CI, 0.936–0.966) for arthritic shoulder measurement. Interrater reliability of the vault method was 0.908 (95% CI, 0.867–0.937) for normal shoulder measurement and 0.905 (95% CI, 0.871–0.930) for arthritic shoulder measurement. Intra- and interrater reliabilities exceeded 0.85 for glenoid version measurements with both measuring methods in all analyses.

The values of glenoid version measured with the conventional method were concentrated between -5° and 5° (range, -8.9° to 16.7°), and those with the vault method were between 5° and 15° (range, 3.2° to 19.7°) (Figure 4A). The distribution of the values of version was significantly larger in the conventional method than in the vault method (p = 0.030). A positive number means that there is retroversion, and a negative number indicates that there is anteversion of the glenoid. The average glenoid retroversion was 1.1° ± 3.2° when calculated with the conventional method and 8.9° ± 2.7° when calculated with the vault method for normal shoulders. The retroversion value measured with the vault method was significantly larger than the value measured with the conventional method (p < 0.001) (Figure 5). In the normal shoulder group, the dominant shoulder showed larger retroversion of the glenoid than the nondominant side both in the conventional method (1.4° ± 3.4° on the dominant shoulder and 0.8° ± 3.1° on the nondominant shoulder, p = 0.013) and in the vault method (9.6° ± 2.7° on the dominant shoulder and 8.2° ± 2.6° on the nondominant shoulder, p < 0.001).

Figure 4
figure 4

The histogram of glenoid version measured with the two different methods. (A) The histogram of glenoid version in the normal shoulders. The values measured with the conventional method are concentrated between -5° and 5°, and those with the vault method are between 5° and 15°. The distributions of the values of version are significantly larger with the conventional method than with the vault method (p = 0.030). (B) The histogram of glenoid version measured in the arthritic shoulders. The values are widely distributed from -8.8° to 42.3° with the conventional method and from 1.4° to 56.8° with the vault method. The distributions of the values of version are not different between the conventional method and the vault method in the arthritic shoulder group (p = 0.737).

Figure 5
figure 5

The average values of glenoid retroversion measured with the two different methods. The average glenoid retroversion measured with the conventional method and the vault method. The vault method shows significantly larger retroversion than the conventional method in both normal and arthritic shoulders (p < 0.001 for both).

In the arthritic shoulder group, the values of glenoid retroversion were widely distributed from -8.8° to 42.3° with the conventional method and from 1.4° to 56.8° with the vault method (Figure 4B). No difference was found in their distributions of arthritic shoulders (p = 0.737). The mean glenoid retroversion values of the arthritic shoulder group were larger than the values of the normal shoulder group. The arthritic shoulder glenoid demonstrated a mean of 10.8° ± 9.3° retroversion with the conventional method and a mean of 18.2° ± 9.1° retroversion with the vault method. The vault method showed significantly larger retroversion than the conventional method in the arthritic shoulders (p < 0.001) (Figure 5).

Discussion

Scapular morphology appears to be modular[14]. The scapular body is congruent with the thorax, and together they form the scapulothoracic joint. The glenoid vault is congruent with the humeral head, and together they form the glenohumeral joint. During shoulder arthroplasty, it is important to recognize the respective glenoid version for proper placement of the glenoid component within the vault[1, 15, 16]. Severe glenoid version is one of the risk factors for postoperative loosening[2, 3], and surgical strategy will change with glenoid version[17, 18]. However, the conventional method for measuring glenoid version is greatly influenced by the scapular body shape, which widely varies from straight to round and wavy[19]. In the normal shoulder group of this study, the vault method showed a lower standard deviation and different distribution of the values of version compared to the conventional method, and this may be the result of elimination of the variable scapular body effects. Although the arthritic glenoid also showed a lower standard deviation of glenoid vault version than the conventional glenoid version, their distributions were not different. The wide variations in version were supposed to lead the result. As the rotator cuff muscles originate from the medial border of the scapula, conventional glenoid version might represent the force balance of the rotator cuff. Nevertheless, the glenoid vault version, which eliminates the scapular body effect, is likely to be more important for clinical use than the conventional glenoid version. The vault method showed significantly larger retroversion than the conventional method in both normal shoulders and arthritis shoulders. The conventional glenoid version could possibly underestimate the severity of arthritis.

We can eliminate the scapular body angulation in measuring glenoid version with the glenoid vault method. We can also check the respective glenoid vault shape by inspecting the anterior wall of the vault during arthroplasty, but it will be impossible to assess the conventional version that utilizes the medial border of the scapula. Finally, the glenoid vault version can be evaluated even if the CT scan does not include the entire scapula, which unfortunately happens quite frequently. The vault method showed high intra- and interrater reliabilities in both normal and arthritic shoulders as well as the conventional method. Thus, glenoid vault version can be used as an alternative measuring method for glenoid version. Poon and Ting also focused on the glenoid vault in version measurement, and they reported their original measuring method using an isosceles triangle pictured within the medial end of the glenoid endosteal vault[19]. However, it is important for proper placement of the glenoid component to understand the location of the glenoid vault with respect to the glenoid center. During glenoid replacement, we face the glenoid surface and not the glenoid endosteal vault. In clinical use, we believe that our glenoid vault version could be more useful than their measuring method to assess the severity of arthritis and difficulty of shoulder arthroplasty.

As the scapula is a three-dimensional structure, two-dimensional measurement of glenoid version might be influenced by the scapular position and the gantry angle of the CT scans[11, 13]. Furthermore, the glenoid is known to twist anteriorly to posteriorly[20, 21], and slice selection can change the values of version. For these reasons, we reconstructed three-dimensionally corrected slices to clarify the accurate values of conventional glenoid version and glenoid vault version. Our study is the first computed tomographic analysis of glenoid vault version with three-dimensionally reconstructed slices. In the normal shoulders, the glenoid has almost neutral version when measured with the conventional method and a mean of 9° retroversion with the vault method. The normal glenoid vault is not symmetric, but usually retroverted. The present study also revealed side-to-side differences in glenoid version and glenoid vault version. In the normal shoulders, the dominant side had significantly larger glenoid retroversion than the nondominant side with both the conventional method and the vault method. Crockett et al. reported that professional baseball pitchers had significantly larger glenoid retroversion in dominant shoulders than in nondominant shoulders[22]. The present result was consistent with the past study, and the glenoid is thought to be retroverted in highly demanding situations. The differences between sides appear to occur in the glenoid vault and not in the scapular body.

The 3-mm-interval thickness of CT scans in the normal shoulder group can be a limitation of the present study. The thickness was selected to minimize exposure to radiation because the normal shoulder group dealt with healthy volunteers. More detailed scans might bring more precise results, but our version measurement showed good-to-excellent intra- and interrater reliabilities even with this thickness. Thus, the results appeared to be reliable.

Conclusions

The present study revealed that the glenoid vault method could be clinically utilized as an alternative measuring method for glenoid version in both normal and pathological shoulders. Our results indicated that the glenoid vault is not neutral, but usually retroverted without the influence of the scapular body shape. Dominant shoulders had significantly larger glenoid retroversion than nondominant shoulders, and the side-to-side difference appears to occur in the glenoid vault and not in the scapular body.

References

  1. Hoenecke HR, Hermida JC, Flores-Hernandez C, D'Lima DD: Accuracy of CT-based measurements of glenoid version for total shoulder arthroplasty. J Shoulder Elbow Surg. 2010, 19: 166-171. 10.1016/j.jse.2009.08.009.

    Article  PubMed  Google Scholar 

  2. Farron A, Terrier A, Buchler P: Risks of loosening of a prosthetic glenoid implanted in retroversion. J Shoulder Elbow Surg. 2006, 15: 521-526. 10.1016/j.jse.2005.10.003.

    Article  PubMed  Google Scholar 

  3. Shapiro TA, McGarry MH, Gupta R, Lee YS, Lee TQ: Biomechanical effects of glenoid retroversion in total shoulder arthroplasty. J Shoulder Elbow Surg. 2007, 16: S90-S95. 10.1016/j.jse.2006.07.010.

    Article  PubMed  Google Scholar 

  4. Friedman RJ, Hawthorne KB, Genez BM: The use of computerized tomography in the measurement of glenoid version. J Bone Joint Surg Am. 1992, 74: 1032-1037.

    CAS  PubMed  Google Scholar 

  5. De Wilde LF, Berghs BM, VandeVyver F, Schepens A, Verdonk RC: Glenohumeral relationship in the transverse plane of the body. J Shoulder Elbow Surg. 2003, 12: 260-267. 10.1016/S1058-2746(02)86884-7.

    Article  PubMed  Google Scholar 

  6. Mullaji AB, Beddow FH, Lamb GH: CT measurement of glenoid erosion in arthritis. J Bone Joint Surg Br. 1994, 76: 384-388.

    CAS  PubMed  Google Scholar 

  7. Nyffeler RW, Jost B, Pfirrmann CW, Gerber C: Measurement of glenoid version: conventional radiographs versus computed tomography scans. J Shoulder Elbow Surg. 2003, 12: 493-496. 10.1016/S1058-2746(03)00181-2.

    Article  PubMed  Google Scholar 

  8. Rouleau DM, Kidder JF, Pons-Villanueva J, Dynamidis S, Defranco M, Walch G: Glenoid version: how to measure it? Validity of different methods in two-dimensional computed tomography scans. J Shoulder Elbow Surg. 2010, 19: 1230-1237. 10.1016/j.jse.2010.01.027.

    Article  PubMed  Google Scholar 

  9. Churchill RS, Brems JJ, Kotschi H: Glenoid size, inclination, and version: an anatomic study. J Shoulder Elbow Surg. 2001, 10: 327-332. 10.1067/mse.2001.115269.

    Article  CAS  PubMed  Google Scholar 

  10. Walch G, Badet R, Boulahia A, Khoury A: Morphologic study of the glenoid in primary glenohumeral osteoarthritis. J Arthroplasty. 1999, 14: 756-760. 10.1016/S0883-5403(99)90232-2.

    Article  CAS  PubMed  Google Scholar 

  11. Bryce CD, Davison AC, Lewis GS, Wang L, Flemming DJ, Armstrong AD: Two-dimensional glenoid version measurements vary with coronal and sagittal scapular rotation. J Bone Joint Surg Am. 2010, 92: 692-699. 10.2106/JBJS.I.00177.

    Article  PubMed  Google Scholar 

  12. Kwon YW, Powell KA, Yum JK, Brems JJ, Iannotti JP: Use of three-dimensional computed tomography for the analysis of the glenoid anatomy. J Shoulder Elbow Surg. 2005, 14: 85-90. 10.1016/j.jse.2004.04.011.

    Article  PubMed  Google Scholar 

  13. Budge MD, Lewis GS, Schaefer E, Coquia S, Flemming DJ, Armstrong AD: Comparison of standard two-dimensional and three-dimensional corrected glenoid version measurements. J Shoulder Elbow Surg. 2011, 20: 577-583. 10.1016/j.jse.2010.11.003.

    Article  PubMed  Google Scholar 

  14. Landau JP, Hoenecke HR: Genetic and biomechanical determinants of glenoid version: implications for glenoid implant placement in shoulder arthroplasty. J Shoulder Elbow Surg. 2009, 18: 661-667. 10.1016/j.jse.2008.11.012.

    Article  PubMed  Google Scholar 

  15. Rispoli DM, Sperling JW, Athwal GS, Wenger DE, Cofield RH: Projection of the glenoid center point within the glenoid vault. Clin Orthop Relat Res. 2008, 466: 573-578. 10.1007/s11999-007-0087-1.

    Article  PubMed Central  PubMed  Google Scholar 

  16. Ting FS, Poon PC: Perforation tolerance of glenoid implants to abnormal glenoid retroversion, anteversion, and medialization. J Shoulder Elbow Surg. 2013, 22: 188-196. 10.1016/j.jse.2011.12.009.

    Article  PubMed  Google Scholar 

  17. Nyffeler RW, Sheikh R, Atkinson TS, Jacob HA, Favre P, Gerber C: Effects of glenoid component version on humeral head displacement and joint reaction forces: an experimental study. J Shoulder Elbow Surg. 2006, 15: 625-629. 10.1016/j.jse.2005.09.016.

    Article  PubMed  Google Scholar 

  18. Lewis GS, Bryce CD, Davison AC, Hollenbeak CS, Piazza SJ, Armstrong AD: Location of the optimized centerline of the glenoid vault: a comparison of two operative techniques with use of three-dimensional computer modeling. J Bone Joint Surg Am. 2010, 92: 1188-1194. 10.2106/JBJS.I.00131.

    Article  PubMed  Google Scholar 

  19. Poon PC, Ting FS: A 2-dimensional glenoid vault method for measuring glenoid version on computed tomography. J Shoulder Elbow Surg. 2012, 21: 329-335. 10.1016/j.jse.2011.04.006.

    Article  PubMed  Google Scholar 

  20. Lewis GS, Armstrong AD: Glenoid spherical orientation and version. J Shoulder Elbow Surg. 2011, 20: 3-11. 10.1016/j.jse.2010.05.012.

    Article  PubMed  Google Scholar 

  21. Inui H, Sugamoto K, Miyamoto T, Machida A, Hashimoto J, Nobuhara K: Evaluation of three-dimensional glenoid structure using MRI. J Anat. 2001, 199: 323-328. 10.1017/S002187820100810X.

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  22. Crockett HC, Gross LB, Wilk KE, Schwartz ML, Reed J, O'Mara J, Reilly MT, Dugas JR, Meister K, Lyman S, Andrews JR: Osseous adaptation and range of motion at the glenohumeral joint in professional baseball pitchers. Am J Sports Med. 2002, 30: 20-26.

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Noboru Matsumura.

Additional information

Competing interests

The authors declare that they have no competing interests.

Authors' contributions

NM conceived of the study, analyzed the collected data, and drafted the manuscript. KO and GW recruited the subjects and assembled the database. HI and PC analyzed the collected data. YT supervised the writing of the paper and gave final approval. All authors read and approved the final manuscript.

Authors’ original submitted files for images

Rights and permissions

This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Cite this article

Matsumura, N., Ogawa, K., Ikegami, H. et al. Computed tomography measurement of glenoid vault version as an alternative measuring method for glenoid version. J Orthop Surg Res 9, 17 (2014). https://doi.org/10.1186/1749-799X-9-17

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/1749-799X-9-17

Keywords