Effect of medial arch-heel support in inserts on reducing ankle eversion: a biomechanics study

Daniel TP Fong1,2, Mak-Ham Lam1,2, Miko LM Lao3, Chad WN Chan1, Patrick SH Yung1,2,3, Kwai-Yau Fung1,3, Pauline PY Lui1,2 and Kai-Ming Chan1,2*

Author Affiliations

1 Department of Orthopaedics and Traumatology, Prince of Wales Hospital, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, China

2 The Hong Kong Jockey Club Sports Medicine and Health Sciences Centre, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, China

3 Gait Laboratory, Department of Orthopaedics and Traumatology, Alice Ho Miu Ling Nethersole Hospital, Hong Kong, China

For all author emails, please log on.

Journal of Orthopaedic Surgery and Research 2008, 3:7 doi:10.1186/1749-799X-3-7

Published: 20 February 2008

Abstract

Background

Excessive pronation (or eversion) at ankle joint in heel-toe running correlated with lower extremity overuse injuries. Orthotics and inserts are often prescribed to limit the pronation range to tackle the problem. Previous studies revealed that the effect is product-specific. This study investigated the effect of medial arch-heel support in inserts on reducing ankle eversion in standing, walking and running.

Methods

Thirteen pronators and 13 normal subjects participated in standing, walking and running trials in each of the following conditions: (1) barefoot, and shod condition with insert with (2) no, (3) low, (4) medium, and (5) high medial arch-heel support. Motions were captured and processed by an eight-camera motion capture system. Maximum ankle eversion was calculated by incorporating the raw coordinates of 15 anatomical positions to a self-compiled Matlab program with kinematics equations. Analysis of variance with repeated measures with post-hoc Tukey pairwise comparisons was performed on the data among the five walking conditions and the five running conditions separately.

Results

Results showed that the inserts with medial arch-heel support were effective in dynamics trials but not static trials. In walking, they successfully reduced the maximum eversion by 2.1 degrees in normal subjects and by 2.5–3.0 degrees in pronators. In running, the insert with low medial arch support significantly reduced maximum eversion angle by 3.6 and 3.1 degrees in normal subjects and pronators respectively.

Conclusion

Medial arch-heel support in inserts is effective in reducing ankle eversion in walking and running, but not in standing. In walking, there is a trend to bring the over-pronated feet of the pronators back to the normal eversion range. In running, it shows an effect to restore normal eversion range in 84% of the pronators.